Profile of the Brandenburger Liner

ProfileCircular, oval, arch and special profiles
Diameters DN 150 – 1600
Lengths up to 300 metres, depending on DN
Techn. values Modulus of elasticity / Young modulus DIN EN 1228 = 14.200 N/mm² (long-term: 11,180 N/mm²)

Resin

Our pipe liners are offered in two different versions. For the domestic sewage range, a UP resin (unsaturated polyester, acc. to DIN 18820 group 3; type 1140), which is temperature resistant up to 50 °C with normal sewage.

The second version is a VE resin (vinyl ester, acc. to DIN 18820 group 5; type 1310), which is recommendable for industrial wastewater. The resistance against chemicals depends on their concentration and temperatures up to 70 °C can be withstood.

Glass

We use ECR Ultrapipe glass exclusively, which was developed together with our supplier specifically for the production of the BB2.5. The material thickness of the glass fibre composite is 0.7 mm. This effects an efficient application of the material, because the deviation to the statically necessary wall thickness lies at 0.6 mm maximum. Cost advantages for the project calculation are the result.

Our glass fibre, which is sewn onto the entire surface of each individual glass roll, forms a homogeneous surface in the pipe liner, which improves the flow properties in the sewer and ensures the durability against wear as well as cleaning in the sewer.

Wear coating

In meeting the requirements of the Advisory Leaflet DWA M143-3, our pipe liner is resistant against abrasion for 50 years of use in the sewer. The glass-fibre-matt bonded wear protection layer is 0.1 mm thick.

Foils

The 3-layer structure of the pipe liner includes, in addition to the GFRP web, a transparent inner foil as well as a grey UV-protective coated, external foil.

Inner foil

The inner foil used, with 120μ, is a two-layered transparent foil. The basic material is PE for ensuring the integrity of the foil during calibration and a thin layer of PA which serves as a styrene barrier.

External foil

The external foil used by Brandenburger is a 220μ thick, three-layered PE/PA/PE foil. The PA layer functions here as a styrene barrier. The foil has the special feature of a laminated PE fibre on the inner side. This provides the pipe liner with an especially good stability for installation in the sewer.

AEP / integrated preliner / sliding protective foil

Our BB2.5 liner features an additional external protection for better protection during drawing in at no extra cost as of a diameter of DN 600. This PVC woven foil features enormous tensile strength and is applied to the liner as a second protection against mechanical damage.

Packaging

Each of our produced pipe liners is packed into an own wooden crate at no extra cost. This is adapted to the ordered pipe liner and manufactured individually for each customer in our own carpenter's shop. The wood used is adapted to the specific needs of the construction site.

The subsequent shipping of the materials to the construction site is planned by our order processing department. We cooperate with a transport specialist to make a hassle-free construction site workflow possible.